268 UNIVERSAL IMPACT TESTER
หมวดหมู่สินค้า: Plastic testing and processing
24 ตุลาคม 2567
ผู้ชม 14 ผู้ชม
- This pendulum type Charpy impact tester can automatically conduct the test cycle, and is capable of testing at extremely low temperatures (as low as -70°C).
- Test conditions are inputted via touch screen and a maximum of 210 specimens can be tested continuously.
- Due to the high capability of the refrigerating system, it is both time and cost efficient when compared to any other model.
JIS K7110、K7111-1、ASTM D256、ISO 179、180
Specifications are subject to change without notice. |
|
Temperature Range |
-70 °C to 80 °C (Refrigerator) |
Hammer |
Please consult. |
Anvil |
Automatic Specimen Setting Device, Rejection Device for Tested Specimens |
Test Specimens |
70 pcs × 3 Cassettes (Total 210 pcs) |
Software |
Windows Compatible |
Option |
Mini Printer (Thermal Dot Method), Specimen Size Measuring Device |
Power Source |
AC 200 V, 3-Phase, 30 A, 50/60 Hz |
Air Source |
0.5 MPa or More |
Dimensions/ Weight (Approx.) |
W1,300 × D1,460 × H1,970 mm、900 kg |