<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>ISO 1133 &#8211; Smartphat</title>
	<atom:link href="https://smartphat.com/en/products/iso-1133/feed/" rel="self" type="application/rss+xml" />
	<link>https://smartphat.com/en</link>
	<description>The Leading Material Testing Solution Hub</description>
	<lastBuildDate>Fri, 23 Oct 2026 08:09:51 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updateperiod>
	hourly	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>

<image>
	<url>https://smartphat.com/wp-content/uploads/2026/05/cropped-โลโก้-32x32.png</url>
	<title>ISO 1133 &#8211; Smartphat</title>
	<link>https://smartphat.com/en</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>MELT FLOW INDEX TESTER (MANUAL) No.120-FWP | YASUDA SEIKI</title>
		<link>https://smartphat.com/en/melt-flow-index-tester-manual/</link>
		
		<dc:creator><![CDATA[wpx_smart]]></dc:creator>
		<pubDate>Wed, 04 Mar 2026 12:02:26 +0000</pubDate>
				<guid ispermalink="false">https://smartphat.com/?post_type=product&#038;p=687</guid>

					<description><![CDATA[MFI Melt Flow index in production <span class="">Issues such as unstable injection pressure, workpiece warpage, or inconsistent plastic quality between batches are often caused by variations in. </span><b class="" data-path-to-node="5" data-index-in-node="196">Melt Flow Rate </b>No.120-FWP (Melt Flow Index Tester) is a manual-operation instrument designed for determining MFR/MVR values. It utilizes an encoder-based displacement measurement system with a resolution of 0.0018 millimeters and supports data analysis via graphical plots.]]></description>
										<content:encoded><![CDATA[<h2>Key Feature</h2>
<ul>
<li>
<p data-path-to-node="8,0,0"><b data-path-to-node="1,0,0" data-index-in-node="0">Accurately measure melt Flow index:</b> Determine the MFR (Melt Mass-Flow Rate) and MVR (Melt Volume-Flow Rate) to evaluate the quality and melting behavior of plastic pellets prior to the manufacturing process.</p>
</li>
<li>
<p data-path-to-node="8,1,0"><b class="" data-path-to-node="1,1,0" data-index-in-node="0">Easy to use and highly accurate:</b> Designed for manual operation, the system ensures stable temperature control within the melting barrel and supports testing according to both Procedure A and Procedure B.</p>
</li>
<li>
<p data-path-to-node="8,2,0"><b data-path-to-node="1,2,0" data-index-in-node="0">Fully compliant with international standards:</b> Covers test methods in accordance with ISO 1133, ASTM D1238, JIS K7210, and other standards within the plastics industry.</p>
</li>
<li>
<p data-path-to-node="8,3,0"><b data-path-to-node="1,3,0" data-index-in-node="0">Easily adjust the applied load and test conditions:</b><span class=""> Standard test weights and accessories for specimen cutting are available, selectable based on the type of plastic being tested.</span></p>
</li>
</ul>
<h2 class="wp-block-heading is-style-none"><span class="epb-font-size" data-fontsize="28px">Reference Standards</span></h2>
<h3>JIS K 6719-1/2, K 6921-2, K 6922-2, K 6923-1, K 6924-1, K 6926-2, K 7210-1, ISO 1133-1, ASTM D1238</h3>
<h2><b>Specification</b></h2>
<div style="width: 100%; overflow-x: auto; -webkit-overflow-scrolling: touch;">
<table style="min-width: 600px; border-collapse: collapse; display: table !important; width: 100%; font-family: sans-serif; font-size: 14px;">
<thead>
<tr style="display: table-row !important; background-color: #f8f9fa;">
<th style="display: table-cell !important; border: 1px solid #ddd; padding: 12px; font-weight: 600; text-align: left; min-width: 250px;">Specification</th>
<th style="display: table-cell !important; border: 1px solid #ddd; padding: 12px; font-weight: 600; text-align: left;">Details</th>
</tr>
</thead>
<tbody>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Hangings</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">1 Hanging</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Die</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">φ2.095 ± 0.005 mm, L8.000 ± 0.025 mm</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Piston</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">Head Diameter φ9.474 ± 0.007 mm, Head Length L6.35 ± 0.10 mm</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Cylinder</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">Inner φ9.550 ± 0.007 mm, L160 mm</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Temperature Range</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">Max. 400 °C</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Initial Weight</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">0.325 kgf</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Additional Weight</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">1.20 ∼ 21.60 kgf <span style="font-size: 12px; color: #666;">(μ Please refer to options below for available weight sizes)</span></td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Test Method</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">• <strong>Method A:</strong> Manual <span style="font-size: 12px; color: #666;">(Option: Automatic Cutter)</span><br />
• <strong>Method B:</strong> Automatic</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Data Processing</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">• <strong>Method A:</strong> Automatic <span style="font-size: 12px; color: #666;">(Measuring the weight of the cut off specimen is done by hand)</span><br />
• <strong>Method B:</strong> Automatic</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Method B Measuring</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">Rotary Encoder</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Standard Specification</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">SD Card Slot, LAN Port</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Option</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; line-height: 1.5;">Mini Printer, Method A Air Pressure Type Automatic Cutter, Manual Type Die Plug, Safety Cover with Interlock Attached, Half Die, Air Pressure Type Automatic Loader (No.120-FWP-W)<br />
<span style="font-size: 13px; color: #333;">• <strong>Additional Weight Sets:</strong> 1.20, 2.16, 3.80, 5.00, 10.00, 21.60 kgf.</span></td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Accessories</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-size: 13px;">Cleaning Rod (Die &amp; Cylinder), Injection Rod, Funnel, Die Gauge, Method A Cutting Knife, Spirit Level, Gauze</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Power Source</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">AC 100 V, 1-Phase, 15 A, 50/60 Hz<br />
<strong>or</strong><br />
AC 200 V, 1-Phase, 10 A, 50/60 Hz</td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Air Source</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">0.5 MPa or greater <span style="font-size: 12px; color: #666;">(For Method A Pneumatic Type Weight Loading Device Specification)</span></td>
</tr>
<tr style="display: table-row !important;">
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px; font-weight: 600; background-color: #fdfdfd;">Dimensions / Weight (Approx.)</td>
<td style="display: table-cell !important; border: 1px solid #ddd; padding: 10px;">No.120FWP: W660 × D450 × H1,020 mm / 75 kg</td>
</tr>
</tbody>
</table>
</div>
<h2 data-path-to-node="17">FAQ Section</h2>
<p data-path-to-node="10"><b class="" data-path-to-node="10" data-index-in-node="0">Q: What does the MFR (Melt Mass-Flow Rate) value obtained from a testing machine indicate?</b></p>
<p data-path-to-node="11"><span class="">A:</span><span class=""> The MFR (Melt Flow Rate) value indicates how easily or difficultly a plastic material flows when heated. A high MFR value means the plastic flows easily, making it simpler to process via injection molding, though it may result in lower mechanical strength. Conversely, a low MFR value indicates that the plastic is more resistant to flow—often due to longer molecular chains—which necessitates specific adjustments to the temperature and pressure settings of the injection molding machine.</span></p>
<p data-path-to-node="12"><b class="" data-path-to-node="12" data-index-in-node="0">Q: How does the manual model No.120-FWP differ from the automatic models (such as No.120-SAS or No.120-LABOT)?</b></p>
<p data-path-to-node="13"><span class="">A:</span><span class=""> รุ่น No.</span><span class="">The 120-FWP model is operated manually, requiring the user to perform tasks such as cutting the plastic strand, weighing the sample, and cleaning the melt barrel; it is well-suited for moderate testing workloads. In contrast, the automated version utilizes a computer-controlled system to handle both the cutting of the extrudate and the cleaning of the barrel, making it ideal for high-volume testing and helping to eliminate operator-related variability.</span></p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
<!--
Performance optimized by W3 Total Cache. Learn more: https://www.boldgrid.com/w3-total-cache/?utm_source=w3tc&utm_medium=footer_comment&utm_campaign=free_plugin

Page Caching using Disk: Enhanced 

Served from: smartphat.com @ 2026-10-29 17:06:18 by W3 Total Cache
-->