GEER TYPE AGING OVEN NO.102

Gear-type accelerated material aging oven with internal air circulation, operating according to specified standards.

The test specimens will be suspended in a chamber maintained at the specified temperature for a designated period to accelerate the degradation process. Afterward, the specimens will be visually inspected and their physical properties measured (e.g., tensile testing) to evaluate thermal degradation properties, such as those of plastics or rubber.

The tested items include automotive parts., Televisions and Computers Exposure to heat affects the lifespan of polymers. Therefore, it is necessary to evaluate the thermal degradation properties of each type of material.

Key Feature

  • Testing to predict tire service life: Heat Aging Tester for Plastics and Rubber.

  • Temperature Range:Room temperature + 20°C to 300°C.
  • Rotation of the workpiece suspension platform: Rotation speed 7.5 ± 2.5 rpm.
  • Damper Control: S-Type Model: Manual control of air intake/exhaust vents. SA Type: Automatic air opening/closing control.
  • Supports international standards covering: ผลิตตามมาตรฐาน ISO 188, JIS K 6257, ASTM D573, UL-746B และ IEC 60216-4-1

  • Technical Highlights: It enables precise, real-time control of airflow velocity and the air exchange rate within the chamber. Temperature is regulated with high accuracy (±1°C), and test history can be viewed via the touchscreen, which also displays air exchange rate graphs for data analysis.

  • A wide range of options: There is a standard model available. No.102 and the stackable model. No.103 (Stackable Type) To save space in the laboratory.

Reference Standards

JIS A5756、B7757、C3005、K6257、K6723、K7212、K7368、ASTM D573、D5374、D5423、E145、UL-746B、IEC-60216-4-1、ISO 188、4577

Accelerated weathering tester : This test chamber features an internal air circulation control system that allows for the setting of air exchange rates (cycles per hour) by selecting between two airflow speeds: low (0.5 ± 0.1 m/s) and high (1.0 ± 0.2 m/s). The unit is equipped with an airflow control system that manages intake from the bottom and exhaust from the top, facilitating turbulent air circulation and ensuring uniform heat distribution.

Geer Type Aging Oven 1

 

Setting Test Conditions According to Standards 

Setting Test Conditions According to Standards

 

Accelerated Aging Test Apparatus for Predicting Material Lifespan  Geer Aging Oven No. 102-SHF-S/SA

 

Accelerated Aging Tester for Predicting Material Lifespan Geer Aging Oven No. 102 SHF SSA

 

 

Yasuda Accelerated Aging Testers come in two models: adjustable air vent in/out.Manual and automatic operation via touch screen

Both modelsThe device will automatically calculate the air exchange rate via the touch screen.

Adjust the air intake and outlet.

 

The device is equipped with a room air temperature sensor, which is an important value for calculating the air exchange rate. It transmits the measured temperature for calculating the air exchange rate. Real-time Can control the maximum temperature. 300 Degree Celsius

The device will automatically calculate the air exchange rate.

 

 

For the automatic model, if the room temperature changes, the device will automatically adjust the air vents to maintain the air exchange rate, ensuring that the testing conditions are controlled in accordance with the specified standards.

Graph of the Relationship Between Air Exchange Rate and Temperature

บันทึกประวัติการทดสอบการทดสอบ อุณภูมิทดสอบ, Air exchange rate, The room temperature is displayed on the touchscreen for easy use.

Graph of the Relationship Between Air Exchange Rate and Temperature

 

Specification

 

Specification SHF-S SHF-SA
Model Characteristics Equipped with air exchange rate measurement/display via touch panel.
Damper: Opened/closed manually.
Equipped with air exchange rate measurement/display via touch panel.
Damper: Automatic Damper Control.
Inner dimensions W450 × D450 × H500 mm
Entire Heated Space Volume 225,225 cm³
Temperature range Room Temperature + 20 to 300 °C
Air velocity Low: 0.5 ± 0.1 m/s, High: 1.0 ± 0.2 m/s (Controlled via touch panel)
Air Exchange Rate Measurement Power Consumption Method
Air Exchange Rate Control Adjustable between 3 to 10 times/hour, 5 to 20 times/hour, or over 60 times/hour
Hanger Rotation Speed 7.5 ± 2.5 rpm
Safety Device Overheat Detection Device, Circuit Breaker
Accessories Specimen Hanger (2 stages), Clip (40 pcs), Shelf (2 pcs)
Option CSV Output, Analog Voltage Output, UL Type Air Exchange Rate 100 to 200 times/hr modification
Power AC 200 V, 3-Phase, 30 A, 50/60 Hz
*When configured with UL Type Air Exchange Rate (100 to 200 times/hr): AC 200 V, 3-Phase, 40 A, 50/60 Hz
Dimensions / Weight (Approx.) W1,180 × D700 × H1,560 mm / 300 kg W1,250 × D700 × H1,650 mm / 305 kg
Reference Standards JIS: A5756, B7757, C3005, K6257, K6723, K7212, K7368
ASTM: D573, D5374, D5423, E145
UL: 746B  |  IEC: 60216-4-1  |  ISO: 188, 4577

FAQ Section

Q: How does a Geer aging oven differ from a standard heating oven?

  • A: The Geer Aging Oven is specifically designed in accordance with testing standards. It features a system that maintains uniform internal airflow, ensures precise air exchange rates, and utilizes a rotating specimen rack to guarantee consistent thermal aging across all samples—capabilities not found in standard ovens.
  • Q: Which model should be chosen if laboratory space is limited?

    A: Model Recommendations No.103 Stackable Type This model is designed to be stacked vertically, saving space, while retaining the exact same functionality and test specifications as the standard No.102 model.

  • Q: Which testing standards does this Geer-type oven model support?

    A: Complies with various key international standards, such as ISO 188, ISO 4577, ASTM D573, ASTM D5423, UL-746B, IEC 60216-4-1, and JIS K6257 / K7212.

©︎2026 SMART PHAT GLOBAL CO., LTD. All Rights Reserved.